Número de pieza
Desmilitarización
Vigencia
UOM
NIIN
Número de pieza:
11153545
NSN
Número de acciones nacionales:
TXT
Descripción:
S Electrical Insulation Sleeving
Código de nombre del artículo:
61626
MRC:
The maximum voltage the insulating materials of the item will withstand without resulting in disruptive discharge or deterioration,expressed in volts.AAPB
Dielectric Withstanding Voltage In Volts:
200.0
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.ABJH
Tempurature Rating:
-55.0 degrees celsius and 150.0 degrees celsius
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Any acceptable
Main Body Inside Diameter:
0.490 inches after unrestricted recovery
Main Body Inside Diameter:
1.120 inches as supplied
First Branch Inside Diameter:
0.490 inches after unrestricted recovery
First Branch Inside Diameter:
1.060 inches as supplied
Second Branch Inside Diameter:
0.490 inches after unrestricted recovery
Second Branch Inside Diameter:
1.060 inches as supplied
Distance From Intersecting Centerline Of Main Body To End Of First Branch:
3.320 inches after unrestricted recovery
Main Body Wall Thickness:
0.100 inches as supplied
Main Body Wall Thickness:
0.100 inches after unrestricted recovery
First Branch Wall Thickness:
0.100 inches as supplied
First Branch Wall Thickness:
0.100 inches after unrestricted recovery
Second Branch Wall Thickness:
0.100 inches as supplied
Second Branch Wall Thickness:
0.100 inches after unrestricted recovery
Distance From Edge Of Main Body To Intersecting Centerlines:
3.420 inches after unrestricted recovery
Angle Between Main Body And Second Branch Centerlines In Deg:
10.0 as supplied
Angle Between Main Body And Second Branch Centerlines In Deg:
22.5 after unrestricted recovery
MRC:
The maximum rated load in tension applied in a longitudinal direction,per unit of cross-sectional area,that the material can withstand without rupture.CQBC
Min. Tensile Strength (psi):
1500 pounds per square inch
MRC:
Flexible,capable of being bent,turned or twisted,within limits,without breaking,or rigid,resisting change of form,inflexible.FLEX
Flexibility:
Flexible
MRC:
A characteristic of light that can be specified in terms of luminance,dominant wavelength,and purity.HUES
Color:
Black
MRC:
The element,compound,or mixture of which an item is fabricated,excluding any surface treatment.MATL
Material:
Rubber chloroprene
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Rubber chloroprene class cr
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Transition-y