Número de pieza
Desmilitarización
Vigencia
UOM
NIIN
Número de pieza:
11-3029
Desmilitarización:
No
Vigencia:
Unidad de medida:
NIIN:
006493420
NSN
Número de acciones nacionales:
6625-00-649-3420 6625006493420
TXT
Descripción:
Insulation Breakdown Test Set
INC
INC
Código de nombre del artículo:
16408
MRC:
Indicates the type of termination provided on the wire.ABCC
Wire Termination Type:
Prod
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
10.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
8.250 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
8.000 inches
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
115.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
60.000 hertz
MRC:
A measurement of the longest dimension of a wire lead.AFSC
Wire Lead Length:
60.000 inches
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Portable
MRC:
Indicates the type of output current whether alternating,direct,or both.ANPN
Output Current Type:
Dc
MRC:
An indication of the type of meter.ANTH
Meter Type:
Ammeter
MRC:
The number of meters provided.ANTJ
Meter Quantity:
1
MRC:
An indication of the scale range.APSK
Scale Range:
+0.0/+1.0 milliamps
MRC:
The output voltage rating at which the item is designed to operate.AQYB
Output Voltage Rating:
1.000 kilovolts
MRC:
The amount of apparent power,as distinguished from true power,for which the item is rated.AQYE
Volt-ampere Rating:
500.00
MRC:
Indicates the type of indicator used to show a leakage condition.AQYK
Leakage Indicator Type:
Meter
MRC:
The number of test leads provided with the item.AQYL
Test Lead Quantity:
2
MRC:
The number of alternating current phases.FAAZ
Phase:
Single