Número de pieza
Desmilitarización
Vigencia
UOM
NIIN
Número de pieza:
081-08158-02
NSN
Número de acciones nacionales:
TXT
Descripción:
Band Pass Filter
Código de nombre del artículo:
00209
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
+0.0/+50.0 degrees celsius
MRC:
The frequency at which the insertion loss is measured per function,and to which all related attenuation loss measurements are referred.AHAJ
Reference Frequency Per Function:
9.5 hercules NO.5599.1 pulses per second
MRC:
The frequency at which the insertion loss is measured per function,and to which all related attenuation loss measurements are referred.AHAJ
Reference Frequency Per Function:
9.5 hercules NO.5599.1 two phase to two phase
MRC:
The frequency at which the insertion loss is measured per function,and to which all related attenuation loss measurements are referred.AHAJ
Reference Frequency Per Function:
9.5 megahertz 1ST band pass 1ST function
MRC:
The frequency at which the insertion loss is measured per function,and to which all related attenuation loss measurements are referred.AHAJ
Reference Frequency Per Function:
9.5 megahertz 2ND band pass 2ND function
MRC:
The total opposition per function with load (resistive and reactive) presented by the device to the source (asa c42.65,paragraph 65.08.399).AHAU
Input Impedance Per Function W/load:
50.0 ohms 1ST band pass
MRC:
The total opposition per function with load (resistive and reactive) presented by the device to the source (asa c42.65,paragraph 65.08.399).AHAU
Input Impedance Per Function W/load:
50.0 ohms 2ND band pass
MRC:
The total opposition per function with source across input (resistive and reactive) presented by the device to the load (asa c42.65,paragraph 65.08.402).AHAV
Output Impedance Per Function W/source Across Input:
50.0 ohms 2ND band pass
MRC:
The total opposition per function with source across input (resistive and reactive) presented by the device to the load (asa c42.65,paragraph 65.08.402).AHAV
Output Impedance Per Function W/source Across Input:
50.0 ohms 1ST band pass
MRC:
The total opposition per function with source across input (resistive and reactive) presented by the device to the load (asa c42.65,paragraph 65.08.402).AHAV
Output Impedance Per Function W/source Across Input:
50.0 ohms 1ST band pass 1ST function
MRC:
Indicates the type of principal circuitry per function interconnected within the item to produce the desired frequency versus attenuation characteristics.AHBL
Principal Circuitry Type Per Function:
Inductance-capacitance blank
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Hermetically sealed
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
4 threaded stud
MRC:
The ratio per function of the power delivered to the load before insertion of the filter to the power delivered to the load after insertion of the filter,expressed in decibels.CQDR
Insertion Loss At Reference Frequency Per Function In Decibels:
5.0 blank
MRC:
Indicates the functional type and number of terminals providing electrical connection to the item.CQDW
Functional Terminal Type And Quantity:
2 tab solder lug input 1ST function
MRC:
Indicates the functional type and number of terminals providing electrical connection to the item.CQDW
Functional Terminal Type And Quantity:
2 tab solder lug output 2ND function
MRC:
The chemical compound or mechanical mixture properties of which the body is fabricated.CQRG
Body Material:
Metal
MRC:
The difference,per function,between the limiting frequencies within which performance,in respect to some characteristic,falls within specified limits.CRBB
Frequency Band Width Per Function:
9.00 megahertz 1ST band pass and 10.00 megahertz 1ST band pass
MRC:
The difference,per function,between the limiting frequencies within which performance,in respect to some characteristic,falls within specified limits.CRBB
Frequency Band Width Per Function:
9.00 megahertz 2ND band pass and 10.00 megahertz 2ND band pass
MRC:
The difference,per function,between the limiting frequencies within which performance,in respect to some characteristic,falls within specified limits.CRBB
Frequency Band Width Per Function:
9.00 megahertz 1ST band pass and 10.00 megahertz 1ST band pass 1ST function
MRC:
The difference,per function,between the limiting frequencies within which performance,in respect to some characteristic,falls within specified limits.CRBB
Frequency Band Width Per Function:
9.00 megahertz 2ND band pass and 10.00 megahertz 2ND band pass 2ND function
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Rectangular terminal/terminals on one surface