Número de pieza
Desmilitarización
Vigencia
UOM
NIIN
Número de pieza:
05-504900
NSN
Número de acciones nacionales:
TXT
Descripción:
Pre Wire Wound Variable Resistor
Código de nombre del artículo:
37408
MRC:
The number of individual elements.AAPN
Section Quantity:
1
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Rectangular w/mounting holes/slots
MRC:
A measurement of the longest dimension of a terminal,in distinction from width.ABJT
Terminal Length:
0.500 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
0.844 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
0.290 inches
MRC:
The length of a straight line which passes through the center of a mounting hole,and terminates at the circumference.ABTB
Mounting Hole Diameter:
0.093 inches
MRC:
The length of a straight line which passes through the center of a shaft,and terminates at the circumference.ABWV
Shaft Diameter:
0.125 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
1.250 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
0.290 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
0.344 inches
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the shaft.AEDX
Shaft Style:
Round slotted
MRC:
Indicates the type of facility or arrangement provided for moving the variable contact(s).AEFD
Actuator Type:
Single shaft
MRC:
The center to center distance between terminals.AEHT
Center To Center Distance Between Terminals:
0.700 inches
Lateral Distance Between Mounting Hole Centers:
1.000 inches
MRC:
The number of mounting facilities provided.AKPV
Mounting Facility Quantity:
2
MRC:
The position of the terminal/s/ for making connection to an item.APXH
Terminal Location:
Lower adjacent side two rows
MRC:
The means of attaching the item.AXGY
Mounting Method:
Unthreaded hole and terminal
MRC:
The center to center distance between the rows of terminals.AYQR
Center To Center Distance Between Terminal Rows:
0.100 inches
MRC:
A measure of the opposition to the flow of direct or alternating current per section.CQCC
Electrical Resistance Per Section:
500.000 kilohms single section
MRC:
The center to center distance between the center terminal and the outside terminal.CQCM
Center To Center Distance Between Center Terminal And Outside Terminal:
0.300 inches
MRC:
The limits of permissible variation in the electrical resistance value per section of an item from its rated value,expressed in percent.CRSS
Resistance Tolerance Per Section In Percent:
-10.0/+10.0 single section
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
3 wire lead