Número de pieza
Desmilitarización
Vigencia
UOM
NIIN
Número de pieza:
0131a0026
Unidad de medida:
No qup EA
NSN
Número de acciones nacionales:
Código de nombre del artículo:
00724
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The number of turns of conductive material forming the winding.ABHY
Turn Quantity:
50-1/2 single component 1ST winding
MRC:
The number of turns of conductive material forming the winding.ABHY
Turn Quantity:
250-1/2 single component 2ND winding
MRC:
The length of a straight line which passes through the center of a mounting hole,and terminates at the circumference.ABTB
Mounting Hole Diameter:
0.118 inches single group and 0.126 inches single group
MRC:
Indicates the type of inductance included on the item.ACYF
Inductance Type:
Fixed
MRC:
The value(s) of inductance inherent in the item.ACYV
Inductance Rating:
1.00 millihenries single component 1ST WINDING25.00 millihenries single component 2ND winding
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
1.0 kilohertz single component
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
0.512 inches
MRC:
The length of a straight line which passes through the center of the body,and terminates at the outside circumference.ADAR
Body Outside Diameter:
0.784 inches
MRC:
The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
Maximum Operating Temp:
80.0 degrees celsius
MRC:
The number of individual /not electrically connected/ windings.AKDX
Winding Quantity:
2 single component
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Fully enclosed
MRC:
The number of mounting facilities provided.AKPV
Mounting Facility Quantity:
1 single group
MRC:
The means of attaching the item.AXGY
Mounting Method:
Unthreaded hole single group
MRC:
The means by which the rating is determined.BKPL
Rating Method:
Electrical single component all winding and winding turns single component all winding
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Tinned wire leads and color coded lead
MRC:
The size of the conductor which forms the winding on the item.CQPZ
Winding Conductor Size:
0.01003 inches american wire gage single component 1ST WINDING0.00795 inches american wire gage single component 2ND winding
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
4 wire lead