						Información de la pieza
						1 each connection for hp and lp gages inlet and outlet connections for union type
					 
				 
						
				
					NSN
				
				
					Número de acciones nacionales:
				
				
			 
			
				
					TXT
				
				
					Descripción:
				
				
					Fluid Pressure Regulating Valve				
			 
			
				
				
					Código de nombre del artículo:
				
				
					27565				
			 
										
					
						MRC:
						The basic material of which the body is fabricated.AAFZ
					 
					
						Body Material:
					
					
						Nickel-copper alloy  QQ-N-281,  class a					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
					 
					
						Body Style:
					
					
						Angle					
				 
							
					
						MRC:
						The element, compound,or mixture of which the stem is fabricated,excluding any surface treatment.ABEP
					 
					
						Stem Material:
					
					
						Nickel-copper alloy  QQ-N-281,  class b					
				 
							
					
						MRC:
						Items furnished as accessories which are not specified elsewhere.ABFF
					 
					
						Furnished Items:
					
					
						Automatic relief valve					
				 
							
					
						MRC:
						The type of service with which the item is designed to be used.ACKL
					 
					
						Media For Which Designed:
					
					
						Air					
				 
							
					
						MRC:
						A narrative description of the type of end connection.ACKM
					 
					
						First End Connection Type:
					
					
						Threaded external boss					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the end.ACKN
					 
					
						First End Style Designator:
					
					
						Gasket seal					
				 
							
					
						MRC:
						Designates the thread diameter,series/type,and number of threads per specific measurement scale.ACLJ
					 
					
						First End Thread Size And Series/type Designator:
					
					
						1.188-16 un					
				 
							
					
						MRC:
						A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.ACLK
					 
					
						First End Thread Class:
					
					
						2A					
				 
							
					
						MRC:
						The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.ACLL
					 
					
						First End Thread Direction:
					
					
						Right-hand					
				 
							
					
						MRC:
						Indicates whether or not the second end is identical to the first end.ACLR
					 
					
						Second End Relationship With First End:
					
					
						Identical					
				 
							
					
						MRC:
						The part that controls the flow through the item.ADQU
					 
					
						Flow Control Device:
					
					
						Poppet					
				 
							
					
						MRC:
						The element,compound,or mixture of which the flow control device is fabricated.ADQV
					 
					
						Flow Control Device Material:
					
					
						Nickel-copper alloy  QQ-N-281,  class b					
				 
							
					
						MRC:
						The number of end connections included in the item.ADQZ
					 
					
						End Connection Quantity:
					
					
						2					
				 
							
					
						MRC:
						The minimum to maximum limits of outlet pressure of the item.AEVA
					 
					
						Outlet Pressure Range:
					
					
						+0.0/+100.0 pounds per square inch					
				 
							
					
						MRC:
						Indicates the basic design type used for regulating the item.AEVN
					 
					
						Regulation Type:
					
					
						Manual single stage					
				 
							
					
						MRC:
						The means used to manually adjust the item.AEVP
					 
					
						Manual Control Method:
					
					
						Knob					
				 
							
					
						MRC:
						The seat design of the valve stem.AEVQ
					 
					
						Valve Stem Design:
					
					
						Single seat					
				 
							
					
						MRC:
						The means of providing resistance to the media passing through a valve,whereby the valve is actuated to regulate the flow.AEVR
					 
					
						Valve Loading Method:
					
					
						Spring					
				 
							
					
						MRC:
						The maximum pressure of the media on the inlet side at which an item is designed to operate.AEVZ
					 
					
						Maximum Inlet Pressure Rating:
					
					
						700.0 pounds per square inch					
				 
							
					
						MRC:
						An indication of whether or not a filter is included.AEWF
					 
					
						Filter:
					
					
						Included